{"id":1930,"date":"2022-09-14T01:00:50","date_gmt":"2022-09-14T01:00:50","guid":{"rendered":"https:\/\/minutemanups.com\/?p=1930"},"modified":"2022-09-14T17:57:10","modified_gmt":"2022-09-14T17:57:10","slug":"in-depth-line-interactive-vs-online-upss","status":"publish","type":"post","link":"https:\/\/minutemanups.com\/fr\/in-depth-line-interactive-vs-online-upss\/","title":{"rendered":"In-depth: Line Interactive vs Online UPSs"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<\/p>\n<h2>Line Interactive vs Online UPS: Which system is right for you?<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-6782\" src=\"https:\/\/minutemanups.com\/wp-content\/uploads\/2021\/06\/EXR-Rack-Tower-Web-300x240.jpg\" alt=\"\" width=\"223\" height=\"178\" \/>This post will focus on the differences between the line interactive and online UPSs in order to find the best fit for your power needs.<\/p>\n<p>While both UPSs provide full protection from\u00a0major power problems, such as surges, spikes, sags, blackouts, and brownouts, they differ in a few significant areas. Simply put, an online UPS offers a higher level of protection than a line interactive at a higher cost. More specific areas where the two types differ include sine wave output, voltage regulation, and double-conversion inversion.<\/p>\n<h2>Sine Wave Output<\/h2>\n<p>There are three types of wave currents: <strong>square<\/strong>,\u00a0<strong>simulated sine<\/strong>, and\u00a0<strong>true sine<\/strong>. While each wave alternates between positive and negative to create a current, the three are vastly different.<\/p>\n<p>Square waves are typically produced by lower-end equipment and, despite cost benefits, may put a strain on the connected equipment that can lead to operation problems.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1932 aligncenter\" src=\"https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/Picture2.jpg\" alt=\"\" width=\"864\" height=\"152\" srcset=\"https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/Picture2.jpg 864w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/Picture2-600x106.jpg 600w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/Picture2-300x53.jpg 300w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/Picture2-768x135.jpg 768w\" sizes=\"auto, (max-width: 864px) 100vw, 864px\" \/><\/p>\n<p>The next step up is a compromise between power quality and cost with a simulated sine wave. While this wave is still less than ideal, the shape of the wave more closely resembles a pure sine wave and therefore, offers a better quality current. With the exception of the EnterprisePlus LCD, all of Minuteman\u2019s line interactive UPSs employ this simulated sine wave to deliver utility power to equipment.<\/p>\n<p>Finally, the best quality wave is the true or pure sine wave. This is the ideal wave for both equipment performance and longevity. Power transitions smoothly between positive and negative to <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1933\" src=\"https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/Picture1.jpg\" alt=\"\" width=\"356\" height=\"62\" srcset=\"https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/Picture1.jpg 865w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/Picture1-600x105.jpg 600w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/Picture1-300x52.jpg 300w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/Picture1-768x134.jpg 768w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/>create the perfect wave and ensure the best quality power is delivered to equipment. While this wave produced a great performance and is safe for sensitive equipment, it does come at a higher cost. Minuteman\u2019s online UPSs all come with true sine wave output, as well as one line interactive unit, the <a href=\"https:\/\/minutemanups.com\/fr\/uninterruptible-power-supply\/exr-series-line-interactive-uninterruptible-power-supply\/\">EXR Series<\/a>, which simulates a true sine wave.<\/p>\n<p>Therefore, with the exception of the EXR series, Minuteman\u2019s line interactive units offer a simulated sine wave while the online UPSs have true sine wave output across all units.<\/p>\n<p>Learn more about sine wave differences and benefits here: <a href=\"https:\/\/minutemanups.com\/fr\/sinewave-vs-simulated-sinewave\/\">Sine Wave vs. Simulated Sine Wave<\/a><\/p>\n<h2>Voltage Regulation<\/h2>\n<p>A line interactive UPS has two options when it comes to dealing with power, switch to battery power or buck\/bump the power level to normal with an automatic voltage regulator (AVR).\u00a0 An AVR acts as a sort of gatekeeper and each unit has a range that covers slightly above and slightly below normal which is 110V. For instance, a range can be between 100v and 120v. So here are the options for the current: 1.) If the current coming from the wall is normal then it goes right through. 2.) If the current is abnormal but still within a certain range, the voltage regulator will either boost the current up to normal or bring it down to normal. 3.) However, if the current is abnormal and outside of the range then the UPS will switch to battery power just like the standby UPS.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1820 aligncenter\" src=\"https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/lineinteractive.jpg\" alt=\"\" width=\"877\" height=\"224\" srcset=\"https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/lineinteractive.jpg 877w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/lineinteractive-600x153.jpg 600w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/lineinteractive-300x77.jpg 300w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/lineinteractive-768x196.jpg 768w\" sizes=\"auto, (max-width: 877px) 100vw, 877px\" \/><\/p>\n<p>AVR becomes very beneficial in areas with unreliable power because power can run through the UPS with voltage regulation pretty much indefinitely, unlike a battery where the power only lasts a certain amount of time.<\/p>\n<h2>Double-Conversion Inversion<\/h2>\n<p>Instead of employing a battery to prevent downtime, online UPSs only have one option to protect against power problems and that\u2019s conversion. As complicated as \u2018double-conversion inversion\u2019 sounds, it\u2019s a relatively simple concept. Firstly, an AC current is one that can run long distances but is not as high quality as DC power. Conversely, DC power is very high quality, but only for short distances, like the distance through a UPS. Thus, every current enters an online UPS as AC then is converted into DC, whether it is normal or not, and exits the unit as AC again. Essentially, an online UPS cleans up any current, ensuring the purest most high-quality current is entering the equipment attached to it.<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-1821\" src=\"https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/online.jpg\" alt=\"\" width=\"877\" height=\"224\" srcset=\"https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/online.jpg 877w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/online-600x153.jpg 600w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/online-300x77.jpg 300w, https:\/\/minutemanups.com\/wp-content\/uploads\/2020\/02\/online-768x196.jpg 768w\" sizes=\"auto, (max-width: 877px) 100vw, 877px\" \/><\/p>\n<h2>How to Decide<\/h2>\n<p>While an online UPS is top-of-the-line protection, it can be costly. These units are best suited for sensitive mission-critical equipment that handles very sizable amounts of power. Many people are looking for great protection that won\u2019t hurt the budget too much, which is where the line interactive units come into play. Line interactive UPSs are a great balance between protection and quality. Minuteman\u2019s line interactive UPSs range from 550VA to 3000VA to ensure the right fit for every system.<\/p>\n<p>Minuteman\u2019s online <a href=\"https:\/\/minutemanups.com\/fr\/uninterruptible-power-supply\/endeavor-lcd-on-line-uninterruptible-power-supply\/\">Endeavor LCD Series <\/a>offers units with true sine wave output and AC-DC-AC conversion ranging from 1kVA to 10kVA, making it ideal for sensitive, high-powered equipment. Minuteman\u2019s line interactive UPSs have simulated sine waves with voltage regulation, making them a great compromise between cost and quality.<\/p>\n<p>With its simulated true sine wave output, voltage regulation, and versatility, the <a href=\"https:\/\/minutemanups.com\/fr\/uninterruptible-power-supply\/exr-series-line-interactive-uninterruptible-power-supply\/\">EXR Series<\/a> is a perfect bridge between the online and line interactive units. This UPS has factors typically associated with both the online and line interactive while also having independent battery bypass. Independent battery bypass ensures that after normal power is restored, the unit will move from battery power or voltage regulation back to utility power automatically.<\/p>\n<p>Check out Minuteman\u2019s\u00a0<a href=\"https:\/\/minutemanups.com\/fr\/uninterruptible-power-supply\/\">online<\/a>\u00a0and\u00a0<a href=\"https:\/\/minutemanups.com\/fr\/uninterruptible-power-supply\/\">line interactive series<\/a>\u00a0to choose the right level of UPS for your needs.<\/p>\n<p>&nbsp;<\/p>\n<p class=\"zemanta-related-title\">Related articles across the web<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] Line Interactive vs Online UPS: Which system is right for you? This post will focus on the differences between the line interactive and online UPSs in order to find&hellip;<\/p>\n","protected":false},"author":8,"featured_media":6782,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[33],"tags":[],"yst_prominent_words":[52,1085,670,662,668,671,666,654,652,643,641,672,669,663,659,658,1590,647,644,673],"class_list":["post-1930","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ups","category-33","description-off"],"featured_image_src":"https:\/\/minutemanups.com\/wp-content\/uploads\/2021\/06\/EXR-Rack-Tower-Web-e1663178195837.jpg","author_info":{"display_name":"Marketing","author_link":"https:\/\/minutemanups.com\/fr\/author\/marketing\/"},"jetpack_featured_media_url":"https:\/\/minutemanups.com\/wp-content\/uploads\/2021\/06\/EXR-Rack-Tower-Web-e1663178195837.jpg","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/posts\/1930","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/comments?post=1930"}],"version-history":[{"count":6,"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/posts\/1930\/revisions"}],"predecessor-version":[{"id":8379,"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/posts\/1930\/revisions\/8379"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/media\/6782"}],"wp:attachment":[{"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/media?parent=1930"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/categories?post=1930"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/tags?post=1930"},{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/minutemanups.com\/fr\/wp-json\/wp\/v2\/yst_prominent_words?post=1930"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}