ENDEAVOR 6 & 10KVA TOWER®

ON-LINE UNINTERRUPTIBLE POWER SUPPLY

ENDEAVOR 6 & 10KVA TOWER® ONLINE UNINTERRUPTIBLE POWER SUPPLY

True online UPSs for sensitive electronic equipment and critical servers, network devices, and phone systems

The Minuteman® Endeavor™ 6 & 10kVA Tower Series UPS combines transient free pure sine wave output and extended runtime capability for critical applications. A front-panel LCD display provides visual notification of the UPS status, including AC input status, battery status, and UPS fault indication.

APPLICATIONS

  • High-Density Installations
  • Enterprise Network Installations
  • Network Corporate Servers
  • Telecom/VoIP Systems
  • Extended Runtime

Download Product Brochure | Download Product User Manual

The Endeavor® 6 & 10kVA Tower Series is yet another option for applications that require the best protection available. This feature-rich, single-phase, true online UPS has been designed to support large loads for network data centers, remote network closets, education networks, and other mission-critical applications.

Endeavor® 6 & 10kVA Tower Standard Features

  • True online, double-conversion topology
  • Single-phase, 208 input, with configurable output voltages: 120/208/220/230/240VAC
  • Isolation transformer for full-load 120VAC support
  • Higher output power factor (208 = 90%)
    – 1.0 (with 20 internal batteries)
    – 0.9 (with 18 internal batteries)
    – 0.8 (with 16 internal batteries)
  • Smaller, compact case design
  • Real-time LCD display
  • EPO port standard
  • Simultaneous communication ports (USB/RS232/SNMP Option Card)
  • Extended runtime via external battery packs
  • Internal Maintenance Bypass

WARNING: This product can expose you to chemicals, including lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to: www.P65warnings.ca.gov/product

Network Management and Power Monitoring Software

Power management via SNMP Communication

Optional Network management via SNMP card

  • NetAgent-SNMP-ED

Power Monitoring Software

UPS management software via USB or RS232

For more information, please contact us

FEATURES
ED6KTF
ED10KTF
GENERAL
Maximum Power Capacity
6000VA
10000VA
Default Watt Capacity*
6000 Watts
10000 Watts
Power Factor*
1.0
Topology
Double-Conversion On-Line
Input Type
Hardwire Terminal Block (L-N-G)
Output Type
Hardwire Terminal Block (L-N-G)
INPUT
Number of Phases
Single - Phase
Nominal Voltage
208VAC ~ 240VAC
Acceptable Input Voltage
0 – 300VAC
Voltage Range
110 – 300VAC ±3%
Power Factor Correction
≥99% at full load
Frequency Limits
50/60Hz ±4Hz
Low Voltage Transfer Point
110VAC ±3% at 0-60% Load
176VAC ±3% at 60%-100% Load
High Voltage Transfer Point
120VAC ±3% at 0-60% Load
186VAC ±3% at 60%-100% Load
Input Protection
Re-settable Circuit Breaker and Fuse
OUTPUT: ONLINE
Nominal Range
240VAC (208/230/240 configurable) / 120VAC
Voltage Regulation
±2%
Frequency Range
50/60Hz ±4Hz
Efficiency (Online Mode)
≥89% (at Full Load)
OUTPUT: BATTERY
Waveform Type
True Sine Wave
Nominal Voltage
240VAC (208/230/240 configurable) / 120VAC
Voltage Regulation
±2%
Frequency Range
50/60Hz +/-0.1Hz (unless synchronized to utility)
Voltage T.H.D.
≦  2% @ 100% Linear Load; ≦ 8% @ 100% Non-linear Load
Dynamic Response
200ms to normal voltage±2%
Transfer Time
0 ms
Slew Rate
60V/ms
Crest Factor
2.6:1 max
Overload Capacity
≥100.1% - ≤110% for 30 secs. / ≥110.1% - ≤130% for 10 secs. / ≥130.1% for 1 sec
BATTERY
System Voltage
240VDC
Battery Type
Sealed, Non-Spillable, Maintenance Free, Valve Regulated Lead Acid (VRLA)
Internal Battery Quantity (Default)
20
Runtime: Full Load (Minutes)
5 minutes
3 minutes
Runtime: Half Load (Minutes)
14 minutes
9 minutes
SURGE PROTECTION
Surge Energy Rating
880J
Surge Current Capability
1000A
Surge Response Time
8us
Surge Voltage Let-through
2KV
ENVIRONMENTAL
Audible Noise at 1m (3-ft.)
<55dB at 1 meter
<58dB at 1 meter
Operating/(Storage) Temperature
0°C ~ +40°C / (-15°C ~ +60°C)
Relative Humidity
10 – 95% Non-condensing
Altitude
<1000m to Full Power (De-rate by 1% for every 100m above 1000m)
PHYSICAL
Net Size – LxWxH (mm)
22.1” x 9.8” x 32.5” (561.1 x 250 x 826.5)
Shipping Size – LxWxH (mm)
28.5” x 14.6” x 37.0” (725 x 370 x 940)
Net Weight – (Kgs.)
237 lbs. (107.5)
274.5 lbs. (124.5)
Shipping Weight (Kgs.)
272.3 lbs. (123.5)
309.8 lbs. (140.5)
REGULATORY
Safety and Approvals
cTUVus, CE, RoHS2
EMC Verification
FCC Class A
Warranty
3 years parts and labor
NOTE: The output capacity must be reduced to 90% when the output voltage is set to 208 VAC or 120 VAC.

 

Models:

  • ED6KTF – 6000VA/6000W UPS Unit with 208V/240V input with configurable output voltages: 120/208/220/230/240VAC
  • ED10KTF – 10000VA/10000W UPS Unit with 208V/240V input with configurable output voltages: 120/208/220/230/240VAC

External battery pack