ENDEAVOR® 5-10KVA
ENDEAVOR® 5-10KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY
Double conversion rack/tower UPSs with LCD Display for critical IT, telecommunications, and security systems
The Minuteman® Endeavor™ 5-10kVA Series UPS combines transient free pure sine wave output, extended runtime, generator compatibility, and redundant or parallel configurations for critical applications. A front-panel LCD display provides visual notification of the UPS status, including AC input status, battery status, and UPS fault indication.
APPLICATIONS
- High-Density Installations
- Enterprise Network Installations
- Network Corporate Servers
- Telecom/VoIP Systems
- Extended Runtime
Download Product Brochure | Download Product User Manual
Mission critical applications demand the best power quality – Endeavor 5-10kVA systems deliver it in versatile, easily configurable packages that can be tailored to your specific needs.
Endeavor 5-10kVA Upgraded Features
- User-friendly LCD Display:
Minuteman’s familiar LCD interface provides real-time status and control of the unit - Easy order model numbers:
No more individual modules for ordering - Expands the Endeavor product family:
Models up to 10kVA in a rack/tower format allows paralleled systems up to 20kVA in capacity - Output receptacle configurations on some models:
All dual-voltage output models will have standard receptacle configurations - All 5/6kVA models include an L6-30P/pigtail power cord
Parallel Installations Made Easy
- Configure 2 ED 5-10kVA units in parallel for capacity or redundancy
- System automatically switches between parallel for redundancy (N+1) and capacity based on attached load
- Parallel installs – more user-friendly than ever before
LCD Status Panel
The Endeavor 5-10kVA front panel display provides a range of information to users, including:
-
- Unit status indicators
- Load & battery meters
- Power status, runtime
- Scroll, mute, & power controls
- Error codes/faults
The LCD panel is designed so that it can be oriented vertically or horizontally depending on the installation orientation of the UPS.
Electrical Characteristics
Digital Signal Processor
- Reduced number of components in the UPS also reduces the potential for defects or malfunctions
- Digital Signal Processor, (DSP), combines many components into a single processor, increasing the reliability of the UPS and reducing any downtime potential
- Helps ensure stable, quality power and long life span
High Output Power Factor
- All models feature an output power factor of 0.9 which increases the Watt capacity of the units
- Larger capacities in a smaller UPS VA rating can reduce the overall cost of the UPS solution for a specific load requirement
Output T.H.D.
- Endeavor units maintain an output AC signal within 2% of a true sine wave pattern (Total Harmonic Distortion)
- Prevents equipment damage from internal heat build up on sensitive connected equipment
Overload Capacity
- Sudden spikes can occur when supporting IT infrastructure, industrial equipment, security installations or any electrically-driven load
- Endeavor UPSs are designed to support such situations with the ability to absorb up to 150% of its rated load for up to 30 seconds
- Allows the UPS to be sized for maximum capacity without worry of overload and shutdown, providing cost-savings
Independent Battery Bypass
- An independent battery circuit allows the Endeavor UPS to operate in Normal Mode, even with weak, dead, or defective batteries
- Endeavor UPSs monitor internal battery status at regular intervals; If the UPS detects weak or bad batteries, it will engage an audio alarm and also any preconfigured electronic notifications
- Normal AC output will be maintained as long as utility power is supplied within the UPS’ nominal input range
- The UPS will have a constant 120/208/240V signal and protection from any dangerous spikes or surges while allowing time to replace batteries without having to shut down connected equipment
Optional 240V Output
- Endeavor units can be configured from the factory for use with 240V input and output applications for an additional charge
- Include ED-240VAC with Endeavor 5-10 order for 240V configuration
- For more information about this option, please contact your Minuteman representative
Communication Features
Bundled with SentryHD software
- Minuteman SentryHD auto-shutdown and monitoring software included
SNMP-compatible (with SNMP-NET and SNMP-NV6 cards)
- All models include a standard internal communication slot which is compatible with all current Minuteman SNMP card options
- Adding an SNMP-NET or SNMP-NV6 card allows remote management and control over any IP-based network
- The Option card slot and serial communications port can be operated simultaneously, allowing SNMP to be used in conjunction with Minuteman SentryHD software
- SNMP enables SmartECO mode for increased energy savings
Other Features
Minuteman Reliability for Large Applications
- RoHS 2 Compliant:
as defined by the EU for the reduction of hazardous substances in electrical equipment: 2011/65/EU - 3-yr Standard Warranty
covering all parts and labor, as well as non-pro-rated coverage of batteries - 5-year Extended Warranty Plans available
- Platinum Protection Plan
Insures properly connected equipment up to $200,000 (Continental U.S. and Canada only)
Key features include:
- True double-conversion online technology:
Maximum protection for critical equipment - Digital Signal Processor Design
Higher reliability through reduced number of components used in the UPS - Higher power factors (0.9pf)
Increases the real power capacity of each individual model - 120VAC/208VAC models with standard receptacles
Provides flexibility for support of multiple voltages used on connected loads - Real-time LCD status display
See power and unit status, estimated runtime, and more in real time - Parallelable to 20kVA
Scalable capacity to grow with the customer’s loads - 240V input/output configuration optional
Units can be configured for 240V power for an additional charge - Automatic Internal Bypass
The UPS will sound an alarm and go to bypass mode when an internal fault, (either hardware or battery), is detected - Independent Battery Bypass
The unit can operate as a voltage regulator, even with dead or defective batteries - Smart Fan Control
Variable speed fan control maximizes the cooling of the UPS while maintaining optimum efficiency - Cold Start Function
Start UPS even without utility power - Simultaneous Communication Options
Greater flexibility in the management and monitoring of the UPS system
Battery Technology
Extended Runtime Capability
External Battery Pack Chargers
|
Battery Technology
Hot-Swappable Batteries
|
WARNING: This product can expose you to chemicals, including Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to: www.P65warnings.ca.gov/
Software
Get ultimate control over your power with SentryHD
In today’s complex world of data, networks, and software, control and management of applications is vital, especially when it comes to the power that is supplied to these devices.
SentryHD, included free with all current Minuteman UPS systems, is the latest update to Minuteman’s popular Sentry monitoring and management software. This powerful tool provides users and network managers a range of monitoring & managment tools for their power, allowing total control before, during, and after power problems.
With a simple connection to the UPS via USB or RS-232, SentryHD provides the capability to configure UPSs, monitor power, and diagnose issues, all from secure connections on the network. This eliminates wasteful runs around the facility, saving time and money.
Accessories
Extended Runtime Capability
- All models come bundled with a battery pack module
- For protection through extended blackouts, the Endeavor Series can also utilize connections built into each battery pack to connect multiple units, providing virtually unlimited runtime capabilities
Battery Pack Models
Because each UPS has different battery requirements to support its maximum load capacity, the Endeavor 5-10kVA Series uses battery packs sized to match each UPS model.
External Battery Pack Chargers
- ED-BP192CHARGER – charger for BP192RTXL (5 & 6kVA)
- ED-BP240CHARGER – charger for BP192RTXL (8 & 10kVA)
- An optional external battery pack charger is available for applications that requiring extended or extremely long runtimes (5 or more external battery packs)
- These chargers can shorten the recharge time of all the connected battery packs exponentially
- Critical for installation environments that experience frequent outages or long periodic outages
Power Management via SNMP Communication
Optional SNMP-NV6 and SNMP-NET cards allow easy management of UPS without the need of a connected PC or server
- SNMP-NV6
- SNMP-NET
Optional Programmable Relay Card:
- Monitors UPS events
- 6 programmable relay output contacts
- Configurable normal open or normal close for each relay contact
- Configurable UPS shutdown delay time
- Configurable input signal as shutdown UPS or battery test
- Has the ability to protect up to 6 computers unattended shutdown gracefully
WARNING: This product can expose you to chemicals, including Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to: www.P65warnings.ca.gov/
Extended Warranty Plan
5 Full Years of Trouble-free Service – Guaranteed
Minuteman UPSs already ship with the best warranty in the business at 3 years, including non-prorated battery coverage on most products.
Two levels of Extended Warranty Plans are also available on most UPS product lines to provide an additional 2 years of coverage. These plans ensure a full 5 years of trouble-free ownership.
For complete product information, brochures and manuals visit out Media Resources Center.
Product Specification Links
ED5000RTXL | ED5200RTXL ED6000RTXL | ED6200RTXL
ED8000RTXL | ED8200RTXL ED10000RTXL | ED10200RTXL
MODELS
Model - 208/240V Output Only (120V Capable) | ED5200RTXL (ED5000RTXL) | ED6200RTXL (ED6000RTXL) | ED8200RTXL (ED8000RTXL) | ED10200RTXL (ED10000RTXL) |
---|---|---|---|---|
Maximum Power Capacity | 5000VA / 4500W (4556VA / 4100W) | 6000VA / 5400W (5556VA / 5000W) | 8000VA / 7200W (6889VA / 6200W) | 10000VA / 9000W (8889VA / 8000W) |
Topology | Double Conversion Online, True Sine Wave |
Input Plug Type | Hardwire Only (Hardwire / L6-30P/pigtail cord included) | Hardwire Only (Hardwire Only) |
Output Outlet Type | (6 - NEMA 5-15/20R, 1 - L6-20R, 1-L6-30R) | Hardwire Only (8 - NEMA 5-15/20R, 1 - L6-20R, 1 - L6-30R) |
Input | |
---|---|
Single (1Φ 2W + G) | |
Nominal Voltage | 208VAC |
Acceptable Input Voltage | 0 - 300VAC |
Voltage Range | 156 - 280VAC | 180 - 280VAC |
Power Factor Correction | =99% at Full Load |
Frequency Limits | 40 to 70Hz at Full Load |
Low Voltage Transfer Point | 156/180 resets to Utility Power at 166/190VAC or higher |
High Voltage Transfer Point | 280VAC resets to Utility Power at 270VAC or lower |
Input Protection | Resettable Circuit Breaker |
Output: Online | |
---|---|
Voltage Range | 208VAC: 204 - 212VAC |
Voltage Regulation | Nominal +/-2% |
Frequency Range | 50/60Hz, auto sensing, +/-00.1Hz (unless synchronized to utility) |
Efficiency (On-Line Mode) | >90% (Full Load) |
Output: Battery | |
---|---|
Waveform Type | True Sine Wave |
Nominal Voltage | Default: 208VAC, User-selectable:220/230/240VAC |
Voltage Regulation | Nominal +/-2% (until Low Battery warning) |
Frequency | 50/60Hz, +/-0.1Hz |
Votlage T.H.D. | =2% (Linear Load) |
Dynamic Response | +/-5% @ 100% Load change in 30ms |
Transfer Time | 0 ms |
Slew Rate | =1Hz / second |
Crest Factor | 3 : 1 | 2.7 : 1 |
Overload Capacity | =106% - =110% for 10 minutes / =111% - =125% for 5 minutes / =126% - =150% for 30 seconds |
Battery | ||
---|---|---|
System Voltage | 192VDC | 240VDC |
Runtime: Half Load (minutes) | 12 | 11 | 14 | 12 |
Runtime: Full Load (minutes) | 4 | 3 | 5 | 4 |
Surge Protection | |
---|---|
Surge Energy Rating | 1050J |
Surge Current Capability | 6500 Amps total |
Surge Response Time | 1.2µs normal mode; <50µs common mode |
Surge voltage let-through (as a percentage of an applied ANSI C62.41 Cat. B +/-4kV) | <10% |
Noise Filter | normal and common mode EMI/RFI suppression |
Audible Noise at 1m (3 ft.) | <60dBA |
Environmental | |
---|---|
Operating Temperature (max) | 0 to +40°C (+32 to +104°F) |
Storage Temperature | -15 to +50°C (+5 to +122°F) |
Operating/Storage Humidity | 0 ~ 95% Non-Condensing |
Operating Elevation | 0 to 2,000m (0 to +6,562 ft.) |
Storage Elevation | 0 to 15,000m (0 to +49,213 ft.) |
Surge Protection and Filtering | ||
---|---|---|
Surge Energy Rating (Joules) | 140J | 254J |
Surge Protection | |
---|---|
Safety and Approvals | cTUVus (Conforms to UL1778 4th Edition & CSA 22.2 no. 107.3-05), RoHS 2 Certified |
EMC Verification | FCC Class B, CE Certified |
Warranty - Platinum Protection | Three-years parts, labor, and battery (non-prorated); 5-year extended plans available - $200,000 |