MINUTEMAN RPM® LCD SERIES
CONTROL YOUR DEVICES FROM ANYWHERE IN THE WORLD
Like Being Everywhere, All the Time
The Minuteman RPM LCD (Remote Power Manager) Switched PDU series is the ultimate power nerve center for controlling multiple network devices and services. The RPM LCD PDUs allow for remote management, monitoring of PDU vitals, and control of outlets and networked clients.
Power status can be monitored over the network, via a web browser and/or SNMP card, allowing for full control to remotely reboot connected equipment by switching the outlet on and off.
Features include mail notification, threshold sensing, overload alerts, power sequencing, and central management – via the free centralized monitoring software.
Like Being Everywhere, All the Time
The RPM LCD series of products are IP-addressable RPMs that allow administrators and technicians to remotely control the power to connected servers, network equipment, and security devices, eliminating the need for expensive and time-consuming service calls to reboot unresponsive locked-up devices.
Each RPM ELCD PDU also has the capability to perform scheduled shutdowns and startups, offering additional cost savings via reduced energy consumption. When a device experiences a lock-up, the RPM LCD series can automatically notify administrators and users via email or SNMP traps, while also allowing user-configurable actions.
Under Control from Anywhere
Minuteman RPMs offer a secure connection that is accessible from any device with a standard internet browser, including desktop and laptop PCs, smartphones, and tablets. From these devices, users can control and configure all aspects of the device, including:
- Network Connection:Â The RPM is a smart IP-based PDU that connects to your network via CAT5 cable
- Control Individual Outlets:Â Power on/off, reboot, and monitor up to 24 individual devices from a single IP address
- Scheduled Management Actions:Â save power with automatic shutdown and startup of devices over weekends or holidays
- Notifications via SNMP or Email:Â To keep you informed of events such as a server shutdown, the RPM can submit its notifications via email to up to three addresses
RPM Benefits
Utilizing Minuteman’s remote power manager products allows technicians and administrators to:
- Save Time:Â Reboot remote devices in seconds, not minutes or hours
- Increase Productivity:Â Eliminate help desk calls & lost time when a device locks up: RPM notifies & provides automatic reboot capabilities
- Cut Costs:Â Eliminate service calls to remote locations by managing devices from your computer or smartphone
Minuteman RPM Series Standard Features
- IP-addressable Remote Power Manager
- Built-in Web Server to support Remote Power Management
- Event Notifications via Email or SNMP Traps
- Local LCD displays Amps, IP Address, Temperature and/or Humidity
- Daily, Weekly, Monthly & Yearly Power Consumption Data
- 10/100 Base-T Ethernet Port
- IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
- Telnet, SSH Encryption Support
- Radius Authentication
- User Account for Three Different Permissions Management Systems
- Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
- SSL Web Browser for Set Up and Operation
- IP Address Filtering
- Maximum 5,000 Entries for Each Power Consumption Data and Event log
- Remote Firmware Upgrade Support
- SNMP Heart Beat Trap Available
- Reports in Fahrenheit or Celsius
- Export and Import RPM Configuration
- True RMS Current Measurement
- Provides Voltage, Frequency, Power Factor, Active Power, Apparent Power and kWh information
- Remote Outlet On/Off Power Switching
- Remote Outlet Current Monitoring
- User Defined Alarm Thresholds for Warning and Overload
- User Defined Power On/Off Sequence Timing
- Timed & Scheduled On/Off/Reboot Switching
- Alternative Outlet Restart Mode: Memorize Previous Status, Always On or Always Off
- Ping No-Answer Alarm
- Outlet Action via Preset-Event: Including Power Event, Environment Event and Receiving Trap from Other Devices
- Circuit Breaker Protection
- Free Bundle Management Utility
WARNING:Â This product can expose you to chemicals, including Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to:Â www.P65warnings.ca.gov/
Software
Web-based Management Interface Features
RPM1521E’s secure IP-based interface provides access to monitoring, control, and configuration from any internet-enabled device.
• Power up or down ports individually or together; delayed start & shutdown
• Schedule regular startups, shutdowns, or reboots yearly, monthly, weekly, or daily to prevent lockups
• Secure access for multiple users
• Control user access to individual ports
• Configure alerts: email, SMS, SNMP
• Browse event logs to see all activity on device
• Power up and down, reboots, lockups
Accessories
RPM-PROBE Temperature/Humidity Probe
Add temperature and humidity monitoring to the RPM Series with the optional temperature/humidity probe.
Models | RPM158N1LCD | RPM1516N1LCD | RPM1524N1LCD |
---|---|---|---|
Features | |||
All-metal case | Yes | Yes | Yes |
Input Power Cord Length | 10 feet | 10 feet | 10 feet |
Input Circuit Breaker Protection | Yes | Yes | Yes |
Horizontal Installation | Yes | No | No |
0U Vertical Installation | Yes | Yes | Yes |
Maximum Input | 15 Amps | 15 Amps | 15 Amps |
Maximum Output Rating | 15 Amps | 15 Amps | 15 Amps |
Front Panel Receptacles | - | (16) 5-15 R | (24) 5-15 R |
Rear Panel Receptacles | (8) 5-15R | - | - |
Standard Input Connection | IEC320 C20 | IEC320 C20 | IEC320 C20 |
NEMA Input Option | "-15P" | "-15P" | "-15P" |
IEC Input Option | '"-IEC" | '"-IEC" | '"-IEC" |
Hardwire Input Option | '"-HW" | '"-HW" | '"-HW" |
IPv6 Support | Yes | Yes | Yes |
SNMPv3 Support | Yes | Yes | Yes |
Individual & Grouped Outlet Control | Yes | Yes | Yes |
Configurable Auto-Alarm Response | Yes | Yes | Yes |
Auto-ping/Heartbeat Monitoring | Yes | Yes | Yes |
TLS/SSL Secure E-mail Notices | Yes | Yes | Yes |
SNMP or Web Browser Control | Yes | Yes | Yes |
Scheduled Shutdown/Restart | Yes | Yes | Yes |
62368-1 Certification | Yes | Yes | Yes |
Models | RPM208N1LCD | RPM2016N1LCD | RPM2024N1LCD |
---|---|---|---|
Features | |||
All-metal case | Yes | Yes | Yes |
Input Power Cord Length | 10 feet | 10 feet | 10 feet |
Input Circuit Breaker Protection | Yes | Yes | Yes |
Horizontal Installation | Yes | No | No |
0U Vertical Installation | Yes | Yes | Yes |
Maximum Input | 20 Amps | 20 Amps | 20 Amps |
Maximum Output Rating | 20 Amps | 20 Amps | 20 Amps |
Front Panel Receptacles | - | (16) 5-15/20R | (24) 5-15/20R |
Rear Panel Receptacles | (8) 5-15/20R | - | - |
Standard Input Connection | IEC320 C20 | IEC320 C20 | IEC320 C20 |
NEMA Input Option | '"-20P" / "-L20P" | '"-20P" / "-L20P" | '"-20P" / "-L20P" |
IEC Input Option | '"-IEC" | '"-IEC" | '"-IEC" |
Hardwire Input Option | '"-HW" | '"-HW" | '"-HW" |
IPv6 Support | Yes | Yes | Yes |
SNMPv3 Support | Yes | Yes | Yes |
Individual & Grouped Outlet Control | Yes | Yes | Yes |
Configurable Auto-Alarm Response | Yes | Yes | Yes |
Auto-ping/Heartbeat Monitoring | Yes | Yes | Yes |
TLS/SSL Secure E-mail Notices | Yes | Yes | Yes |
SNMP or Web Browser Control | Yes | Yes | Yes |
Scheduled Shutdown/Restart | Yes | Yes | Yes |
62368-1 Certification | Yes | Yes | Yes |
Models | RPM308N1LCD-HW | RPM3016N1LCD-HW | RPM3024N1LCD-HW |
---|---|---|---|
Features | |||
All-metal case | Yes | Yes | Yes |
Input Power Cord Length | 10 feet | 10 feet | 10 feet |
Input Circuit Breaker Protection | Yes | Yes | Yes |
Horizontal Installation | Yes | Yes | Yes |
0U Vertical Installation | Yes | Yes | Yes |
Maximum Input | 30 Amps | 30 Amps | 30 Amps |
Maximum Output Rating | 30 Amps | 30 Amps | 30 Amps |
Front Panel Receptacles | - | (16) 5-15/20R | (24) 5-15/20R |
Rear Panel Receptacles | (8) 5-15/20R | - | - |
Standard Input Connection | Hardwire | Hardwire | Hardwire |
NEMA Input Option | '"-L30P" | '"-L30P" | '"-L30P" |
IEC Input Option | - | - | - |
Hardwire Input Option | - | - | - |
IPv6 Support | Yes | Yes | Yes |
SNMPv3 Support | Yes | Yes | Yes |
Individual & Grouped Outlet Control | Yes | Yes | Yes |
Configurable Auto-Alarm Response | Yes | Yes | Yes |
Auto-ping/Heartbeat Monitoring | Yes | Yes | Yes |
TLS/SSL Secure E-mail Notices | Yes | Yes | Yes |
SNMP or Web Browser Control | Yes | Yes | Yes |
Scheduled Shutdown/Restart | Yes | Yes | Yes |
62368-1 Certification | Yes | Yes | Yes |
Models | RPM204I2LCD-L20P | RPM208I2LCD-L20P | RPM2016I2LCD-L20P | RPM2024I2LCD-L20P |
---|---|---|---|---|
Features | ||||
All-metal case | Yes | Yes | Yes | Yes |
Input Power Cord Length | 10 feet | 10 feet | 10 feet | 10 feet |
Input Circuit Breaker Protection | Yes | Yes | Yes | Yes |
Horizontal Installation | Yes | No | No | No |
0U Vertical Installation | Yes | Yes | Yes | Yes |
Maximum Input | 20 Amps | 20 Amps | 20 Amps | 20 Amps |
Maximum Output Rating | 20 Amps | 20 Amps | 20 Amps | 20 Amps |
Front Panel Receptacles | - | - | (14) C13 / (2) C19 | (21) C13 / (3) C19 |
Rear Panel Receptacles | (4) C13 | - | - | - |
Standard Input Connection | NEMA L6-20P | NEMA L6-20P | NEMA L6-20P | NEMA L6-20P |
NEMA Input Option | - | - | - | - |
IEC Input Option | - | - | - | - |
Hardwire Input Option | '"-HW" | '"-HW" | '"-HW" | '"-HW" |
IPv6 Support | Yes | Yes | Yes | Yes |
SNMPv3 Support | Yes | Yes | Yes | Yes |
Individual & Grouped Outlet Control | Yes | Yes | Yes | Yes |
Configurable Auto-Alarm Response | Yes | Yes | Yes | Yes |
Auto-ping/Heartbeat Monitoring | Yes | Yes | Yes | Yes |
TLS/SSL Secure E-mail Notices | Yes | Yes | Yes | Yes |
SNMP or Web Browser Control | Yes | Yes | Yes | Yes |
Scheduled Shutdown/Restart | Yes | Yes | Yes | Yes |
62368-1 Certification | Yes | Yes | Yes | Yes |
Models | RPM308I2LCD-HW | RPM3016I2LCD-HW | RPM3024I2LCD-HW |
---|---|---|---|
Features | |||
All-metal case | Yes | Yes | Yes |
Input Power Cord Length | 10 feet | 10 feet | 10 feet |
Input Circuit Breaker Protection | Yes | Yes | Yes |
Horizontal Installation | Yes | No | No |
0U Vertical Installation | Yes | Yes | Yes |
Maximum Input | 30 Amps | 30 Amps | 30 Amps |
Maximum Output Rating | 30 Amps | 30 Amps | 30 Amps |
Front Panel Receptacles | - | (14) C13 / (2) C19 | (21) C13 / (3) C19 |
Rear Panel Receptacles | (8) C13 | - | - |
Standard Input Connection | Hardwire | Hardwire | Hardwire |
NEMA Input Option | '"-L30P" | '"-L30P" | '"-L30P" |
IEC Input Option | - | - | - |
Hardwire Input Option | - | - | - |
IPv6 Support | Yes | Yes | Yes |
SNMPv3 Support | Yes | Yes | Yes |
Individual & Grouped Outlet Control | Yes | Yes | Yes |
Configurable Auto-Alarm Response | Yes | Yes | Yes |
Auto-ping/Heartbeat Monitoring | Yes | Yes | Yes |
TLS/SSL Secure E-mail Notices | Yes | Yes | Yes |
SNMP or Web Browser Control | Yes | Yes | Yes |
Scheduled Shutdown/Restart | Yes | Yes | Yes |
62368-1 Certification | Yes | Yes | Yes |