| | 160 VAC/140 VAC/120 VAC/110 VAC ± 5 % (based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0) | | | 160 VAC/140 VAC/120 VAC/110 VAC ± 5 % (based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0) |
| | 175 VAC/155 VAC/135 VAC/125 VAC ± 5 % | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | ≤ 5% @ 205-245VAC THDU < 1.6% @ input and full linear load condition | | | ≤ 5% @ 205-245VAC THDU < 1.6% @ input and full linear load condition |
| | | | | |
| | | | | |
| | | | | |
| | 47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range) | | | |
| | 50Hz ± 0.1% Hz or 60Hz ± 0.1%Hz (Bat. Mode) | | | 50Hz ± 0.1% Hz or 60Hz ± 0.1%Hz (Bat. Mode) |
| | | | | |
Harmonic Distortion (THDU) | Harmonic Distortion (THDU) | <2% (Linear load) <4% (Non-Linear load) | | | <2% (Linear load) <4% (Non-Linear load) |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | 3 hours recover to 95% capacity (for Non-XL models only) | | | 3 hours recover to 95% capacity (for Non-XL models only) |
| | | | | |
| | | | | |
| | | | | |
| | Load level, Battery Level, Alarms, Operating Mode | | | Load level, Battery Level, Alarms, Operating Mode |
| | Input Voltage and Frequency, Output Voltage and Frequency, Battery Backup Time (hours/minutes) | | | Input Voltage and Frequency, Output Voltage and Frequency, Battery Backup Time (hours/minutes) |
| | (3) buttons to turn UPS On/Off, navigate LCD screen & Mute Alarms | | | (3) buttons to turn UPS On/Off, navigate LCD screen & Mute Alarms |
| | | | | |
| | Low battery, Overload, Battery Not Connected, Overcharge, Site Wiring Fault, EPO Enabled, Over Temperature, Charger Failure, Battery Fault, Bypass Out of Range and Bypass Frequency Unstable | | | Low battery, Overload, Battery Not Connected, Overcharge, Site Wiring Fault, EPO Enabled, Over Temperature, Charger Failure, Battery Fault, Bypass Out of Range and Bypass Frequency Unstable |
**PHYSICAL WEIGHT & DIMENSIONS H" x W" x D" / [mm] | | | | | **PHYSICAL WEIGHT & DIMENSIONS H" x W" x D" / [mm] |
| | 3.46” x 17.24” x 16.14” (2U) [88 x 438 x 410] | 3.46” x 17.24” x 16.14” (2U) [88 x 438 x 410] | 3.46” x 17.24” x 20.08” (2U) [88 x 438 x 510] | 3.46” x 17.24” x 24.80” (2U) [88 x 438 x 630] |
| | 17.24” x 3.46” x 16.14” (2U) [438.0 x 87.9 x 410.0] | 17.24” x 3.46” x 16.14” (2U) [438.0 x 87.9 x 410.0] | 17.24” x 3.46” x 20.08” (2U) [438.0 x 87.9 x 510.0] | 17.24” x 3.46” x 24.80” (2U) [438.0 x 87.9 x 629.9] |
| | | | | |
ENVIRONMENT (Electronics) | | | | | ENVIRONMENT (Electronics) |
| | 32°F (0°C) to 104°F (40°C) | | | 32°F (0°C) to 104°F (40°C) |
| | 20-90 % RH @ 0 - 40° C (non-condensing) (32°F - 104°F | | | 20-90 % RH @ 0 - 40° C (non-condensing) (32°F - 104°F |
| | -13°F (-25°C) to 104°F (40°C) BATTERIES (REFRESH Charge @ 3 months) | | | -13°F (-25°C) to 104°F (40°C) BATTERIES (REFRESH Charge @ 3 months) |
| | Less than 50dBA @ 1 Meter | | | Less than 50dBA @ 1 Meter |
MANAGEMENT / COMMUNICATION | | | | | MANAGEMENT / COMMUNICATION |
| | Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC | | | Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC |
| | Power management from SNMP manager and web browser | | | Power management from SNMP manager and web browser |
| | With DB9 or 9 Pin Connector | | | With DB9 or 9 Pin Connector |
| | | | | |
| | CE; EN 62040-2:2006 (C2); EN 62040-1:2008 | | CE; EN 62040-2:2006 (C2); EN 62040-1:2008 | |
* Derate capacity to 80% when the output voltage is adjusted to 200VAC/208VAC. | | | | | * Derate capacity to 80% when the output voltage is adjusted to 200VAC/208VAC. |